Issue: Integra.exe will not close with normal methods after move of data
Modified on: Mon, 17 Aug, 2020 1:53 PM
Issue:Integra.exe will not close with normal methods after move of data
Date Documented: 11 Mar 2019
Symptoms / Error
After moving data from a server where data was located in a different location, Integra.exe will not end after closing the application. High CPU usage is also noted on integra.exe
Cause
This is caused by incorrect pathing within the syscorps.cdx data container.
Fix
Forcefully close integra.exe using task manager.
Delete file C:\Avatar\Integra\SYSTEM\SYSCORPS.CDX
Restart Integra and rebuild table.
Verify fix.
Was this answer helpful?
Yes
No
Sorry we couldn't be helpful. Help us improve this article with your feedback.